The flow is fixed; the incoming water temperature decides the size.

Short answer

Yes, if it is sized for it. Two 2.1 GPM showers need 4.2 GPM of hot water. With 50°F water coming in and a 120°F setting, that takes a 160,000 BTU condensing gas unit; in the cold North, where winter water arrives near 40°F, 199,000 BTU. A heater sized for one shower will run the second one cold.

Size for two showers in your climate

What two showers need, by climate

Two 2.1 GPM showers (4.2 GPM) at 120°F, condensing gas at 0.93 efficiency
ClimateWinter inletRiseGas unitElectric
Warm South (Florida, Gulf coast)70°F50°F120,000 BTU36 kW, 150 A
Mild (Carolinas, Oklahoma)58°F62°F150,000 BTUbeyond one unit
Middle of the US (Ohio, Kansas)50°F70°F160,000 BTUbeyond one unit
Cold North (Minnesota, Maine)40°F80°F199,000 BTUbeyond one unit

The rise is the difference between the water coming in and the temperature you set. It is what sizes a tankless heater, and it is largest in winter, which is why the same two showers need a bigger unit in Minnesota than in Florida. Incoming water temperature by state has the figure for yours.

Why the box’s GPM rating does not settle it

Manufacturers quote maximum flow at a small rise, usually 35°F. At a winter rise of 70 or 80°F the same unit delivers roughly half that. A heater sold as "9.8 GPM" is not a two-shower heater in a cold climate; it is about a 4.5 GPM heater there. Why the GPM rating misleads works through it.

Electric units and two showers

Two showers at a large rise are the limit of whole-house electric tankless. The biggest common units are about 36 kW and need 150 A of dedicated circuits, often more than a house’s whole service can spare. In warm climates electric works; in cold ones, gas or a heat pump tank is usually the practical choice. Low-flow showerheads help: at 3.5 GPM for the pair, a cold-climate house needs 160,000 BTU instead.

Frequently asked questions

What size tankless water heater do I need for 2 bathrooms?
For two showers at once, about 4.2 GPM at your winter rise: a 160,000 BTU condensing gas unit with 50°F incoming water, 199,000 BTU in the cold North.
Why does my tankless go cold when two showers run?
The demand exceeds what the unit can heat at your current temperature rise, usually in winter when incoming water is coldest. Lower-flow showerheads or a larger unit fix it; turning up the set temperature does not.
How many GPM do I need for two showers?
About 4.2 GPM with typical 2.1 GPM showerheads, or 3.5 GPM with 1.75 GPM low-flow heads.
Can an electric tankless run two showers?
In a warm climate, yes, with a large unit on heavy dedicated circuits. In a cold climate two showers at a large rise usually need more power than a home’s electrical service can supply.