Guide
Does a gas tankless water heater need electricity?
Yes, a little, all the time. Without it there is no hot water.
Short answer
Yes. A gas tankless water heater burns gas for heat but needs 120 V electricity to light the burner, run the combustion fan and work the controls. The draw is small: the RU199i, a 199,000 BTU Rinnai, uses 84 W while heating, 1.3 W on standby and up to 148 W when its freeze protection runs. With the power off it will not fire, so a power cut means no hot water.
What the electricity does
- Ignition. There is no standing pilot. Rinnai RU-series (Sensei) units use direct electronic ignition, which sparks the burner each time hot water is drawn.
- The combustion fan. The fan pushes exhaust out through the vent, and the unit checks its speed. No fan, no burner.
- Controls and sensors. A flow sensor tells the unit a tap is open, and the board modulates the gas to hold your set temperature. The wall controller runs on 12 V DC.
- Freeze protection. In cold weather the unit warms its own water passages electrically to keep them from freezing. This is the largest draw.
How many watts a gas tankless uses
| Model | Gas input | Heating | Standby | Freeze protection |
|---|---|---|---|---|
| RU199i | 199,000 BTU | 84 W | 1.3 W | 148 W |
| RU180i | 180,000 BTU | 65 W | 1.3 W | 148 W |
| RU160i | 160,000 BTU | 52 W | 1.3 W | 148 W |
| RU130i | 130,000 BTU | 38 W | 1.3 W | 148 W |
The same sheet lists a maximum current of 4 A and a 10 A internal fuse. Other brands publish their own figures in the installation manual, under electrical specifications; check the one for your model, especially if it has a built-in recirculation pump, which draws more.
Next to the gas, the electricity is a rounding error. The RU199i burns 199,000 BTU an hour, which is 58.3 kW of gas, against 84 W of electricity: 0.14% of the energy going through it. A household whose heater fires for 1 hour a day at full draw and sits on standby the rest of the time uses about 3.4 kWh of electricity a month for it.
What happens in a power outage
The heater stops. With no power there is no spark, no fan and no flow sensor, so the gas valve stays shut and the taps run cold. Gas tank heaters with a standing pilot and a thermocouple-powered gas valve are the ones that keep working in an outage; a tankless unit is not one of them.
The bigger risk is frost. Freeze protection is electric too, so an outage in freezing weather leaves the water inside the heater unprotected. Rinnai’s manual for the RV53E says that if power is lost, or the cold is beyond what the freeze protection handles, you should turn the unit off, close the gas supply and let a tap run at a very low flow, about 0.1 GPM, to keep water moving through it. For freezing weather without power, it says to drain the unit: shut off the cold water and gas, turn the controller off, disconnect the power and open the drain plugs. Do not try to run a heater that has frozen until it has been checked.
Running it from a battery or generator
The load is small enough for a portable power station or a small generator. A 1,000 Wh battery could in principle run an RU199i for about 12 hours of burner time, or its freeze protection for about 7 hours, before inverter losses, which take a share of that. Two things matter more than the size of the battery:
- Grounding. The heater needs a grounded 120 V supply, from a battery or generator as much as from the wall. Check what the installation manual says about generator power before relying on it.
- How it is wired. If the heater plugs in, you can move the plug. If it is hard-wired to a junction box, it needs a transfer switch or an interlock fitted by an electrician.
The outlet and circuit it needs
An ordinary grounded 120 V supply. A 4 A maximum is 27% of a 15 A circuit, so the heater does not need a heavy circuit of its own the way an electric tankless does. Whether it plugs into an outlet or is wired into a junction box, and whether it may share a circuit, is set by the installation manual and your local code. For what an electric tankless needs instead, see what size breaker a tankless water heater needs.